CHAPTER 3
Advanced Functions
82
DIRECT
DESCRIPTION Allows to send any availible radio command directly to the
specified device.
P
ARAMETERS Device Id, wanted command, command parameters
R
ETURNS Result of sent radio command.
R
EMARKS For details please consult the A73x addWAVE User Guide.
E
XAMPLE direct 10820 info
10820 info 255 255 29/8/2006 13:09:19 2.6 2 0 0
84 62 232 6:47 42 65 72 4 900 15 12 0
OK
Gets the information from the specific device.
PING
DESCRIPTION Returns information about the specified device such as the RF
levels, the date and time of the internal real-time clock of the
station, the software version in the station, and the number of
reserved bytes.
P
ARAMETERS The RTU’s ID.
R
ETURNS A string or an error message (for example, ERROR 35 means
timeout). The strings and parameters returned depend on the
remote device type. Following is an explanation of the information
returned:
• Incoming RF is the level recorded by the receiving station.
• Outgoing RF is the level at which the sending station received
the requesting station.
• Pout represents the output power of the transmitter while it is
sending the answer to the ping frame.
• The date/time represents the actual value of the local real-
time clock.
• Ver is the software version of the RTU.
• Clk, stk, and cop contain Adcon-specific information.
• The uptime represents the time the device has operated since
the last reset or internal watchdog reset.
• The battery and internal temperature are self-explanatory.