CHAPTER 3
Operations at the Application Level
77
If you choose headerformat=S, a tag name of, for example, "1234
temperature relay 1" would be printed as "1234".
outputformat=T|S
Specifies the format of the output: a single table with a column
for each TAG (outputformat=T) or one section with one table per
TAG (outputformat=S).
datequote=string
Specifies the quote character for the DATE column (same syntax
like quote=). Default is the same as the string quote.
timequote=string
Specifies the quote character for the TIME column (same syntax
like quote=). Default is the same as the string quote.
statusquote=string
Specifies the quote character for the STATUS column (same
syntax like quote=). Default is the same as the string quote.
headerquote=string
Specifies the quote character for the header lines (same syntax
like quote=). Default is the same as the string quote.
Note: the following parameters may be used for the “Sections”
output format only (outputformat=S):
sectionheader=string
Specifies an additional section header. The header can contain
the following characters:
I for the RTU node ID
N for the full RTU name
S for the first word of the RTU name
•i for the TAG node ID
n for the full TAG name
s for the first word of the TAG name
{text} to include text as literals
status=yes|no
Specifies whether the status of the measurement values is
output in its own column (status=yes) or not (default, or
status=no).