Figure 13. Adding a new A733 RTU
4. If you plan to use the gateway to initialize the RTU’s internal
real-time clock, click the Master checkbox.
5. If you want data from the selected RTU stored on your
gateway, click the Retrieve data checkbox (if the RTU is used
only as a relay station, do not select this option).
6. You can also use this window to set up a route with your new
RTU (applicable only if you selected an A733RTU). To do this,
select an RTU from the left pane and click the right-arrow
button to move it to the right pane. (To remove an RTU from
the route, select it in the right pane and click the left-arrow
button to move it to the left pane.) To change the order of the
relaying stations, select an RTU and click the up or down
arrows. Note that the first station in the list is closer to the
base station and the last station in the list is closer to the RTU.
7. Enter the Phone number of the RTU (applicable only if you
selected an A733GSM/GPRS RTU). The phone number is
supplied to you by your cellular network operator (for more
details, please read also the addWAVE User Guide).